Most compressed air applications can achieve the required air quality by using a refrigerated dryer in combination with proper filtration. However, in cases where compressed air is exposed to freezing temperatures or where the product, process, or equipment is highly sensitive to moisture, Kaeser offers a complete line of desiccant dryers specifically designed to meet low dew points and deliver energy savings.
Kaeser KED | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model | Inlet Flow @ 100 psig (scfm) |
Purge Flow (scfm) |
Air Availlable (scfm) |
Heater (kW) |
Dimensions (in) |
Weight (lb) |
In/Out Conn (in) |
Pre Filter (scfm) |
High- Temp After-Filter (scfm) |
Total Replacement Desiccant< (lb) |
300 | 300 | 21 | 279 | 2.0 | 50 x 46 x 98 | 1570 | 1.5 NPT | 375 | 400 | 420 |
400 | 400 | 28 | 372 | 2.7 | 55 x 52 x 104 | 2130 | 1.5 NPT | 625 | 600 | 708 |
500 | 500 | 35 | 465 | 3.3 | 55 x 52 x 105 | 2130 | 2 NPT | 625 | 600 | 708 |
600 | 600 | 42 | 558 | 4.0 | 57 x 53 x 108 | 2431 | 2 NPT | 780 | 1200 | 1180 |
750 | 750 | 53 | 697 | 5.0 | 62 x 59 x 114 | 2913 | 3 FLG | 1000P | 1200 | 1180 |
900 | 900 | 63 | 837 | 6.0 | 62 x 59 x 114 | 2913 | 3 FLG | 1000P | 1200 | 1180 |
1050 | 1050 | 74 | 976 | 7.0 | 66 x 62 x 113 | 3526 | 3 FLG | 1250P | 1200 | 1420 |
1300 | 1300 | 91 | 1209 | 8.7 | 68 x 63 x 118 | 4250 | 3 FLG | 1875P | 1800 | 1848 |
1500 | 1500 | 105 | 1395 | 10.0 | 82 x 66 x 119 | 6353 | 3 FLG | 1875P | 1800 | 2518 |
1800 | 1800 | 126 | 1674 | 12.0 | 82 x 66 x 119 | 6353 | 3 FLG | 1875P | 1800 | 2518 |
2200 | 2200 | 154 | 2046 | 14.7 | 85 x 73 x 127 | 9620 | 4 FLG | 2500P | 2400 | 3734 |
2600 | 2600 | 182 | 2418 | 17.4 | 85 x 73 x 127 | 9620 | 4 FLG | 3125P | 3000 | 3734 |
3200 | 3200 | 224 | 2976 | 21.4 | 97 x 82 x 125 | 11340 | 4 FLG | 5000P | 4800 | 4754 |